Igniter Tester


Model 4314 Range List
Unit Ranges
4314A 20 200 2k 20k ----- ----- -----
4314AB 20 Rear input 6 pin DIN ----- ----- -----
4314AN 20 200 ----- ----- ----- 2M 20M
4314AP 20 ----- 2k ----- 200k ----- -----
4314B ----- 200 2k 20k ----- ----- -----
4314BN ----- 200 ----- ----- 200k ----- -----
4314C 20 200 ----- ----- 200k ----- 20M
4314GD 20 ----- ----- 20k 200k ----- 20M
4314H ----- 200 2k ----- 200k 2M -----
4314T 20 200 ----- 20k ----- ----- 20M
Resolution 1m 10m 100m 1 10 100 1k
Test Current 10mA 1mA 100A 10A 1A 100nA 10nA
Fail Safe 16mA 1.8mA 180A 18A 1.8A 180nA 18nA
*4314BK
or 4314KB
20 200 2k 20k ----- ----- -----
4314LK 20 200 2k ----- 200k ----- -----
4314UK 20 200 2k 20k ----- ----- -----
Resolution 1m 10m 100m 1 10 ----- -----
Test Current 5mA .5mA 50A 5A .5A ----- -----
Fail Safe 8mA 1.8mA 180A 18A 1.8A ----- -----
4314AN-1 ----- 200 ----- ----- ----- 2M 20M
Resolution ----- 10m ----- ----- ----- 100 1k
Test Current ----- 1mA ----- ----- ----- 100nA 10nA
Fail Safe ----- 1.8mA ----- ----- ----- 180nA 18nA
#4314H ----- 200 2k ----- 200k 2M -----
Resolution ----- 10m 100m ----- 10 100 -----
Test Current ----- 1mA 100A ----- 1A 100nA -----
Fail Safe ----- 1.8mA 180A ----- 1.8A 180nA -----
4314N ----- 200 2k ----- ----- 2M 20M
Resolution ----- 10m 100m ----- ----- 100 1k
Test Current ----- 1mA 100A ----- ----- 100nA 10nA
Fail Safe ----- 1.8mA 180A ----- ----- 180nA 18nA
*Front panel charger input jack and fuse holder
# 2 Volt limiter/clamp open circuit voltage
Customer safety engineered versions with specific ranges and fail safe current levels are available: Contact Valhalla Engineering Department for assistance.