Valhalla logo  
'Manufacturers of Digital Power Analyzers, Digital Wattmeters, Harmonic Power Analyzers, Wideband Spectrum Power Analyzers, ATC Ohmmeters, Micro-Ohmmeters, Milliohm-Meters, Digital Ohmmeters, Igniter Testers, Current Calibrators, AC-DC Active Current Shunts, Hipot Testers, Body Comp Scales and more…'
 
Applications
Igniter 								Testers
Wattmeters
Power Analyzers
Ohmmeters
High Voltage
Calibration
Body Fat Scale
Options
Accessories
Calibration Procedures
Manuals
Specifications
History
Technical Support
Contact Us
Home
 
  DIGITAL IGNITER TESTERS
Valhalla 4314AF User Safe Digital Igniter Tester
4314AF image
4314AF Digital Igniter Tester

Valhalla 4314AF Digital Igniter Tester Features Include:

  • Ultra Safe- Ultra Fail Safe
  • Battery Powered Igniter Tester
  • US Air Force Approved
  • 4314AF Cannot Measure/Recharge Simultaneously
  • 1milliohm Resolution to 20,000 Ohms
  • Fail-Safe Current Limited
  • Mil-Spec Front Panel Connector


specs options


With the 4314AF Valhalla introduces an added safety feature that prevents the possibility of having the charging adapter connected while using the instrument for measurements.

A 6-pin Mil-Spec circular connector (MS3112E10-6S) on the front panel of the 4314AF replaces the four-terminal banana jacks used on the 4314A front panel and the battery charger jack on the 4314A rear panel. This is accomplished by the removal of the rear panel charger jack and including its connections to the instruments charging circuits through the 6-pin front panel connector. Four of the front panel connector pins are used to mate with the measurement adapter cable and the other two pins are for the battery charging cable adapter.

By using separate adapter cables for measurements and charging of the batteries, it ensures that the charge circuit can not be activated at the same time as measurements are being made.

Measurement Adapter Cable:

The measurement adapter cable is a 3 feet long cable with a 6-Pin Mil-Spec circular connector, "MS3116F10-6P" at one end and a 4-Pin Mil-Spec circular connector at the other end. The cable configuration is two twisted pairs with an outer shield. The four wires are connected to four of the connector pins that mate with the front panel connector pins used for 4-wire measurements.

Battery Charging Cable:

A standard 115VAC input wall adapter with an output of 6VDC at 300mA is used for charging the 4314Af batteries. The adapter has a 3 feet cable that the 6-Pin Mil-Spec connector has been attached to. Removing the measurement cable from the 4314AF and connecting the 6-Pin connector of the power adapter cable to the 4314AF front panel connector allows the batteries to be charged.



Specifications:
RANGES 20 200 2000 20000
Resolution 1m 10m 100m 1
Test Current 10mA 1mA 100A 10A
Failsafe 16mA 1.8mA 180A 18A
Customer safety engineered versions with specific ranges and fail safe current levels are available: Contact Valhalla Sales Department for assistance.
  • Accuracy: (180 days 25°C ± 10°C) ± ±0.03% of reading ±0.02% of range.
  • Display: 4 1/2 digit (19999) L.E.D. - 20,000 counts
  • Terminal Configuration: Four-wire Kelvin
  • Overload Indication: Display flashes
  • Maximum Input: 250 VDC or peak AC without damage
  • Operating Temperature Range: 0°C to 50°C
  • Temperature Coefficient: ±.002% per °C (from 0°C to 15°C and 35°C to 50°C)
  • Conversion Rate: Approximately 3 per second
  • Power: Rechargable Ni-Cad batteries & charger (115 VAC 50-60 Hz)
  • Size: 235mm/9" D x 254mm/10" W x 76mm/3" H
  • Weight: 1.6 KG/3.5lbs NET 3 KG/6.5 lbs shipping


BACK TO LIST