Ultra-Safe
Resistance Measurement
The Alpha 4314
Digital Igniter Tester is a portable digital ohmmeter
which has been specifically designed for ultra-safe
resistance testing on explosive devices (i.e. squibs,
detonators). The Alpha 4314 is an Upgrade of the 4314 Series
and now features a new front panel, Range and Fail-Safe LED indicators,
and optional BCD output that can be used to interface
the instrument to the Valhalla Model 1248 Digital Dual Comparator.
Many versions of the 4314 series have had
the unit's circuitry reviewed and approved by a U.S.
Government Safety Board as well as most branches of the
armed forces for specific military programs (i.e. Cruise
Missile).
Designed with
Life Protecting Safety in Mind
There are a
variety of critical military, aerospace and industrial
applications which utilize squibs and other blasting
devices. In each case, it is extremely important that
these devices detonate when required. It is equally
important that these devices do not detonate while being
tested for continuity integrity. To this end, Valhalla equips
each instrument with redundant, dual fail-safe current
limiting network circuitry to insure that the instrument
test currents cannot exceed the specified amount. Even in
the unlikely event of a worst case component failure, the
output current limiting network is still in effect. To
prove that this level of safety is intact in every unit
we ship, a worst case component failure is simulated
during final test with the resulting output current flow is recorded and that data is
attached to the unit.
The Alpha 4314
utilizes a four-wire Kelvin input configuration to
eliminate lead wire length and lead contact resistance
errors. The units are battery powered with a heavy duty
rechargable Ni-Cad pack for portability and line
isolation purposes. An AC adaptor battery charger is
standard. For added convenience and safety, the Alpha 4314
feature an internal switching configuration which
automatically disables the battery charging circuit when
in the operate mode. Alternately, all power is removed
from the output circuitry when in the off/charging
mode.
As with
all Valhalla Digital Ohmmeters and Igniter Testers, the Alpha 4314 is available
with a host of 4-wire probes and cable sets. Consult the
end of this section for complete information on Options and Accessories.
BCD Capability
For
applications requiring data output the Alpha 4314 is available
with "BCD". The "BCD" talk only interface is fully
compatible with our 1248 Dual Limit Comparator. Notice that the BCD Option does not interfere
or change the FailSafe feature of the instrument. Option BCD Data Sheet
Range Selection
The standard version of the Alpha 4314 features a 20, 200, 2k, and 20k Ohm range;
however the user can choose to purchase an instrument with a different configuration.
In the table below are listed the eight possible ranges that can be installed in the Alpha 4314.
When ordering, simply specify the four range numbers you perfer installed in your igniter tester
| Range # | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| Range (ohms) | 20 | 200 | 2k | 20k | 200k | 2M | 20M | 100M |
| Resolution (ohms) | 1m | 10m | 100m | 1 | 10 | 100 | 1k | 10k |
| Test Current (A) | 10mA | 1m | 100u | 10u | 1u | 100n | 10n | 1n |
| FailSafe Current (A) | 16m | 1.8m | 180u | 18u | 1.8u | 180n | 18n | 1.8n |
Option KRC (Reduced Current Output)
Also available is the "KRC" Models that feature a reduced Test and FailSafe Current
| Range # | 1 | 2 | 3 | 4 | 5 |
| Range (ohms) | 20 | 200 | 2k | 20k | 200k |
| Resolution (ohms) | 1m | 10m | 100m | 1 | 10 |
| Test Current (A) | 5mA | 500u | 50u | 5u | 500n |
| FailSafe Current (A) | 8m | 1.8m | 180u | 18u | 1.8u |
Customer
safety engineered versions with specific ranges and fail
safe current levels are available: Contact Valhalla Engineering
Department for assistance.
For your convinience a table listing the old ordering
format is available.
Click Here to View.
|