Ultra-Safe
Low Ohms Resistance Measurement
The Alpha 4314 Low Ohms
Digital Igniter Tester is a portable digital ohmmeter which has
been specifically designed for ultra-safe low resistance testing
on explosive devices (i.e. squibs, detonators). This is the first
model of the 4314 Series Igniter Testers that features a 2Ohm Range
with a resolution of 100uA without compromising the Low Fail Safe
and Test Currents. This Model was especially designed to replace
the Model 4650A no longer in production. Many versions
of the 4314 series have had the unit's circuitry reviewed
and approved by a U.S. Government Safety Board as well as
most branches of the armed forces for specific
military programs (i.e. Cruise Missile).
Designed with
Life Protecting Safety in Mind
There are a
variety of critical military, aerospace and industrial
applications which utilize squibs and other blasting
devices. In each case, it is extremely important that
these devices detonate when required. It is equally
important that these devices do not detonate while being
tested for continuity integrity. To this end, Valhalla equips
each instrument with redundant, dual fail-safe current
limiting network circuitry to insure that the instrument
test currents cannot exceed the specified amount. Even in
the unlikely event of a worst case component failure, the
output current limiting network is still in effect. To
prove that this level of safety is intact in every unit
we ship, a worst case component failure is simulated
during final test with the resulting output current flow is recorded and that data is
attached to the unit.
The Alpha 4314 Low Ohms
utilizes a four-wire Kelvin input configuration to
eliminate lead wire length and lead contact resistance
errors. The units are battery powered with a heavy duty
rechargable Ni-Cad pack for portability and line
isolation purposes. An AC adaptor battery charger is
standard. For added convenience and safety, the Alpha 4314
feature an internal switching configuration which
automatically disables the battery charging circuit when
in the operate mode. Alternately, all power is removed
from the output circuitry when in the off/charging
mode.
As with
all Valhalla Digital Ohmmeters and Igniter Testers, the Alpha 4314 is available
with a host of 4-wire probes and cable sets. Consult the
end of this section for complete information on Options and Accessories.
BCD Capability
For
applications requiring data output the Alpha 4314 is available
with "BCD". The "BCD" talk only interface is fully
compatible with our 1248 Dual Limit Comparator. Notice that the BCD Option does not interfere
or change the FailSafe feature of the instrument. Option BCD Data Sheet
Range Specifications
| Range (ohms) | 2 | 20 | 200 | 2k |
| Resolution (ohms) | 100u | 1m | 10m | 100m |
| Test Current (A) | 10mA | 1m | 100u | 10u |
| FailSafe Current (A) | 16m | 1.8m | 180u | 18u |
|