2575A Specifications
Range Name & Maximum Input Shunt Value DC Accuracy (% of Range) AC Accuracy (% of Range) Frequency Response
100A 0.001Ω ±0.05% ±0.1% DC to 1kHz
20A 0.01Ω ±0.02% ±0.1% [1] DC to 10kHz
2A 0.1Ω ±0.02% ±0.1% DC to 10kHz
200mA ±0.01% ±0.1% DC to 10kHz
20mA 10Ω ±0.01% ±0.1% DC to 10kHz
2mA 100Ω ±0.01% ±0.1% DC to 10kHz
NOTES: [1] AC accuracy is ±0.5% of range above 1kHz
  • Amplifier Characteristics
  • Amplitude Gain: 10.000
  • Gain Accuracy: ± 0.01% 10µV RTI @ DC
  • Frequency Response: ± 0.1% to 10 Khz
  • Input Resistance: Greater than 1010Ω
  • Output Resistance: Less than 0.1Ω
  • Temperature Range: 0 to 50°C
  • Temperature Coefficient: Less than .001% per °C
  • Voltage Drop (before amplifier): 100.00 mV for full scale input current
  • Power: 115/230 VAC 50-60 Hz 12 Watts
  • Size: 3.5"H x 17"W x 10"D (8.9cm x 43.2cm x 25cm)
  • Weight: 8 lbs. (3.6KG) Net 13 lbs. (5.9 KG) Shipping