Valhalla Models 2105 Wide Range
Power Analyzer
|

Valhalla
Scientific's 2105 Digital Power Analyzer |
Valhalla 2105
Power Analyzer Features Include:
- Up to 20
Amps/phase direct (self contained shunt
0.1%)
- Expandable
to 1000 amps (optional,see I-1000 C.T.)
- True Power Measurements, VIcos Ř
- High Accuracy Measurement: 0.15% DC to 5KHz
- Bandwidth~ DC, 40 Hz to 50 KHz
- Zero to Unity Power Factor Response
- Accurate Regardless of Waveform Distortion
- Certificate
of N.I.S.T. traceabilty included at no extra
charge
|
|
 |
 |
|
The Valhalla
2105 Wide Range Digital Power Analyzer (V-A-W displays)
This benchtop single-phase Wide Range Digital Power Analyzer is fully
loaded with measurement features you'd expect on
instruments costing three times the price. The 2105
boasts twin high resolution 4 1/2 digital displays, DC to
50 kHz frequency response, true power measurement, true
RMS voltage and current and built-in peak overload
indicators. The 2105 offers 600, 300, 150 and 30 volt ranges and 20, 2 ans 200m amp ranges.
The Valhalla
2105 power meter is also a great measurement
instrument for college and university motor test
laboratories.
|
|
|
| Specifications |
 |
- Accuracy:
(Voltage and Current True RMS) DC & 40 Hz to 5 KHz:
± 0.1% of reading ± 6 counts
- 5 KHz to 15
KHz: ± 0.5 % of reading ± 6
counts
- 15KHz to 20
KHz: ± 0.75% of rdg ± 6 counts - useable
to 50 KHz with typically 1 % error per 10
KHz
- Maximum
Input: 600 VDC or RMS AC, 1500 V peak
- Displays:
Dual 4 1/2 Digit (20,000 counts) 7 segment
LEDs
- Watts
Accuracy: 25 °C ± 5°C, 1
year
- DC & 40 Hz
to 5 KHz: ± 0.25 % of reading ± 6
counts
- 5 KHz to 10
KHz: ± 0.5% of reading ± 0.5 % of
range
- 10 KHz to
20 KHz: ± 1% of reading ± 1% of
range
- 20 KHz to
50 KHz: additional 1% per 10 KHz above 20
KHz
- Power
Factor Response: Unity (1.000) to zero
(0.000)
- Power
Factor Accuracy: for inputs > than 10 % of full
scale
- DC to 1
KHz: ± 5 counts
- 1 KHz to 5
KHz: ± 10 counts
- 5 KHz to 10
KHz: ± 15 counts
- Extended
current capacity is available using 150 amp and 1000
amp clamp-on current transformers (option"I-150 and
option"I-1000").
- Displays:
Large 4 1/2 Digit (20,000 counts) 7 segment L.E.D.
type
|
|
|
Accessories
The following accessories are compatible with 2105 Wide Range Digital Power
Analyzers:
|
- Current
transformers with a 1000:1 step down ratio (1%
accuracy) include option "I-1000" (1000 amps capacity)
and option "I-150" (150 amp capacity)
- Rack Mount
Adapters - For 19" Racks
- Load
Extension Cord option "X-21" for easy 120 VAC load
connections
- Clamp-on
Current Transformer Option "I-150": Extends AC current
Measurement capability on the 2105 to 150 amps
RMS. The 1000:1 output ratio is 2% accurate from 50Hz
to 400Hz.
- Clamp-on
Current Transformer Option "I-1000": Extends AC current
measurement capability to 1000 amps RMS. The 1000:1
ratio CT is 2% accurate from 50Hz to 400Hz. Data Output
Port Option "X21": Approximately three feet in length
for each half, this convenient adaptor cord plugs
directly into a standard 115V AC power outlet and mates
with the 2105 via heavy duty banana jacks.
Female half provides for quick and easy load connect or
disconnect capability.
|
| Ordering Information
|
| Model 2105
|
Benchtop Power Analyzer |
| Option "I-1000"
|
1000A Current Clamp |
| Option "I-150"
|
150A Current Clamp |
| Option "X-21"
|
Load Extension Cord Option
|
| Option "R-4" |
19" Rack
Adapter |
| Option
"M-2105" |
Additional
User/Maintenance Manual |
|
|
BACK
TO LIST
|