 | DIGITAL WATTMETERS AND HARMONIC POWER ANALYZERS |
Valhalla Models 2410 and 2430 Wideband Spectrum Power Analyzers
|

Valhalla 2400 Series Wideband Spectrum Power Analyzers |
Valhalla 2400
Series Spectrum Power Analyzer Features Include:
- Up to 20
Amps/phase direct (self contained shunt
0.1%)
- Single-Phase(1Ø) and Three-Phase(3 Ø)
- The Three-Phase Power Analyzer puts up to 32 measured values on the screen.
- Broad bandwidth: DC-300kHz
- Wide input range (0.3V - 1000V, 15mA - 40A).
- Suitable for frequency inverter drivers
- Harmonics Analyzer 1-99, Bar charts
- 0.1% or 0.05% accuracy
- True Power Measurements, VIcos Ø
- Wide input range (0.3V - 1000V, 15mA - 40A).
- RS232 or IEEE 488, Centronics’ printer compatible
|
|
 |
 |
|
Our new spectral power analyzer gives you solid performance and simple operation in a compact easy to use package.
Introduction:
Valhalla¹s
state of the art 2400 Series Power Analyzers offer high
performance in both single and three phase. Unlike other
instruments at this price level the 2400 is designed to
operate with extreme signals generated on frequency
inverter drivers. These analyzers provide precise
reliable measurements for any waveform. Large clear
monitor lets you read displayed values from a distance of
four meters.
|
|
Simple to use:
Checking power
to determine the pertinent power parameters of a
frequency inverter driven system is simple. All values
display large letters easily read even in dark rooms. The
user menu makes operation easy.
|
|
Measured values can be:
- Printed,
(Centronics Printer Interface)
- Sent to a PC
via IEEE-488 or RS232 interface
- Sent to a
chart recorder via the analog outputs
You can have
all options that we make available installed in your
instrument.
|
|
|
Extraordinary features, attractive
display:
Much effort
went into the design of the 2400 Power Analyzers to give
the highest performance at low costs.
The analyzer
inputs are all galvanically isolated.
Broad band
DC-300kHz.
Wide input
range (0.3V - 1000V, 15mA - 40A).
Exceptional
common mode rejection for use in frequency inverter
driven systems.
The accuracy is
0.1% (0.05% versions are available).
The bright LCD
monitor displays up to 10 measured values in well legible
9mm high numbers.
The Three-Phase
Power Analyzer puts up to 32 measured values on the
screen.
You have the
choice to visualize wave forms, bar graphs or trend
plots. A unique feature of these instruments allows a
combination of meter mode and graphic mode.
|
|
|
Computed Values :
The new 2400
power analyzer measures, computes, and displays all of
your critical power variable to let you concentrate on
more efficient reliable testing. It is available in
single or three phase versions and combines a wattmeter,
oscilloscope, and a power spectrum analyzer in a single
compact package.
From the
simultaneous and precise voltage and current
measurements, you can measure and monitor all of the
power parameters you need. You can display them in the
format that fits your application.
Current and
voltage. RMS, RM, Peak and Harmonics through the 99th
order.
Power.
Watts, VA, VAR, and Power Factor
Integrated
Measurements. Watt-Hours, VA Hours, VARH and Amp
Hours
General
values. Frequency, Harmonic Distortion, Crest Factor,
Form Factor, and Oscilloscope Display
|
|
Technical Data:
General:
- Display:
graphic display 64 x 120 mm / 240 x 128
pixels
- Operation:
foil keyboard with 11 function keys, menu-driven,
additional remote control via RS232 or IEEE
488
- Mains:
115V/230V ± 15%, 45-65 Hz, 30 VA, fuse T 2A /
1A
- Dimensions:
150 x 230 x 320 mm (H x W x D)
- Weight: 4
kg
- Reference
Temp: 23° C ± 3° C
- Working
temp. range: 0 . 40° C
- Storage
temp. range: -20° C . +50° C
- Climatic
class: KYG according to DIN 40040 (0 - 40°
C)
- Humidity
max.: 85%, annual avg. 65% no dewing
|
Specifications:
| Voltage
|
| Ranges |
.3V, 1V, 3V, 10V,
30V,100V, 300V, 1000V |
| Frequency Range
|
DC, 0.1Hz-300kHz
|
| Crest Factor |
4:1 at 50% full scale
(fs) |
| Input Impedance
|
>1M |
| Common Mode -
50Hz/100kHz |
155dB/95dB |
Standard Accuracy
23°K ±3°K
1Hz-1kHz
DC, 1kHz - 10kHz
10kHz - 100kHz
100kHz - 300kHz
Improved Accuracy
|
±(0.1%rdg + 0.1% range)
±(0.2%rdg + 0.2% range)
±(0.3%rdg + 0.04% range)
±(0.2%rdg + 0.2% range)
±(0.05%rdg + 0.07% range)
|
| Current
|
| Ranges |
15mA, 50mA, 150mA, 500mA,
1.5A, 5A, 1,3,10,30,100,300A |
| Frequency Range
|
DC, 0.1Hz-300kHz
|
| Crest Factor |
4:1 at 50% full scale
(fs) |
| Common Mode -
50Hz/100kHz |
160dB/120dB |
Standard Accuracy
23°K ±3°K
5A Input/Shunt Input
1Hz-1kHz
DC, 1kHz - 10kHz
10kHz - 100kHz
100kHz - 300kHz
Improved Accuracy
|
±(0.1%rdg + 0.1% range)
±(0.2%rdg + 0.2% range)
±(0.3%rdg + 0.04% range)
±(0.3%rdg + 0.04% range)
±(0.05%rdg + 0.07% range)
|
Standard Accuracy
23°K ±3°K
30A Input
1Hz-1kHz
DC, 1kHz - 10kHz
10kHz - 100kHz
100kHz - 300kHz
Improved Accuracy
|
±(0.1%rdg + 0.1% range)
±(0.9%rdg + 0.2% range)
±(0.3%rdg + 0.5% range)
±(0.3%rdg + 0.5% range)
±(0.05%rdg + 0.07% range)
|
| Power |
| Ranges |
80 Ranges corresponding
to the products V x A |
| Frequency Range
|
DC, 0.1Hz-300kHz
|
Accuracy 23°K
±3°K
1Hz-1kHz
DC, 1kHz 10kHz
10kHz 100kHz
|
Add accuracy % of I and
V
PF = 0 to ±1
PF = 0 to ±1
PF = 1
|
| Frequency
|
| 0.1Hz-300kHz, A or V
triggered Accuracy |
±0.1% |
| Computed
Values |
Accuracy; Reactive
Power, Var =
±(VA2-W2)_;
Apparent Power: VA = ArmsVrms;
Power Factor: PF = W/VA;
Crest Factor: CF = Ap/Arms, Vp/Vrms;
Form Factor: FF = At/Arms, Vt/Vrms;
Impedance: Z = Vrms/Arms;
Total Harm Dist: THD = (Irms2 -
Ifund2)_/Irms |
| Integrator
|
| Energy, Charge;
Accuracy - Wh, Vah, Varh, Ah; Basic accuracy of
integrated quantity. |
| Harmonic
|
| Frequency range of
fundamental - 2.5Hz - 100kHz |
| Analysis
|
Accuracy, Harmonic
current and voltage
2Hz-1kHz
1kHz-10kHz
10kHz-100kHz
|
±(0.2% rdg + 0.1% range)
±(0.5% rdg + 0.5% range)
±(0.7%range + 0.1%/kHzrdg)
|
| Display
|
| Blue liquid crystal
graphic display with FL back light; 64x120mm; 128x240
pixels |
| Power |
AC, 50-400Hz;
85V-240V; 2AF/30VA |
| Dielectric
Strength |
Input to case or power
supply
Line input to case
Input to Input
|
2.5kV/50Hz/1minute
1.5kV/50Hz/1minute
4kV/50Hz/1minute
|
| Dimensions
|
H 150mm x W 235mm x
D 320mm
Weight 4Kg |
|
|
Ordering Information:
| Power
Analyzer: |
| 2410-1S: |
Single Phase Basic Model,
0.1% accuracy |
| 2410-1HS: |
Single Phase Power
Analyzer,w/Harmonics & Scope 0.1% accuracy |
| 2410-1HE: |
Single Phase Power
Analyzer, w/ Harmonics or Scope, 0.05%
accuracy |
| 2430-3S: |
Three-Phase Basic Model,
0.1% accuracy |
| 2430-3HS: |
Three-Phase Power
Analyzer,w/Harmonics & Scope 0.1% accuracy |
| 2430-3HE: |
Three-Phase Power
Analyzer, w/ Harmonics or Scope, 0.05%
accuracy |
| Accessories: |
| ACS1: |
Current clamp with connector to 106A shunt input; 0-200A / 0-1000A,
DC-1kHz, 2 %, other ranges and accuracies on request
|
| ACS2: |
Portable printer (106 x
180 x 88mm) with Centronics interface and cable
(weight400gr.) |
| ACS3: |
Soft carrying case for
2400 |
| ACS4: |
Set of test leads, max. 32A, 1.5m (2 red, 2 black) |
| ACS5: |
Shunt input
connector |
| ACS6: |
Service
Manual |
| ACS7: |
Rack Mounting
Kit |
| Options: |
| Option-01: |
RS-232 Interface and Centronics printer output including Windows Operating
Software (95, 98, NT, 2000, ME, XP) to control, read, and store data
|
| Option-02: |
RS-232- and IEEE-488 Interface, Centronics printer output including Windows
Operating Software (95, 98, NT, 2000, ME, XP) to control, read, and store data
|
| Option-03: |
RS-232- and IEEE-488 Interface, Centronics printer output, and 4 analog outputs,
8 analog inputs including Windows Operating Software (95, 98, NT, 2000, ME, XP)
to control, read, and store data, read analog inputs.
inputs |
| Option-03A: |
RS-232 and IEEE-488 Interface, Centronics printer output 4 analog outputs with
provision to also output total power, 8 analog inputs including Windows Operating
Software (95, 98, NT, 2000, ME, XP) to control, read, and store data, read analog
inputs.
inputs |
| Option-04: |
3-Phase current sensors
model 0-100A (supply by 2400), +/- .45% Accuracy |
| Option-05: |
Operating software under
DOS to control 2400, read data and store data via
RS-232 or IEEE-488 (National, Keithly
Interface) |
| Option-06: |
2400 driver for Nat.
Instrument LabView |
| Option-07: |
Standalone software based
on LabView |
| Option-07M: |
Software for Motor Testing
|
| Option-07T: |
Software for Transformer Testing
|
| Option-08: |
TTL-input for external
synchronization |
| Option-09: |
Network to form
artificial neutral (mainly frequency inverter
measurements) |
| Option-10: |
0-300A, 0-3000A flexible current clamps with connector to clamp input of Power Analyzer (1 per phase). 1% 50/60Hz.
|
|
|
BACK TO
LIST
|
|