 | DIGITAL WATTMETERS AND HARMONIC POWER ANALYZERS |
Valhalla 3030A Energy Analyzer
Data Logger
|

Valhalla 3030A Energy Analyzer
Data Logger |
Valhalla 1020A Smart Interface
Module Features Include:
- Power Mains Data Logger
- Accommodates Single Ø and 3-wire Delta and 4-wire Wye
- 3 Voltage Channels ~ 4 Current channels
- Accommodates inputs from CT’s to 600A (6 F.S. Auto-Ranges)
- Accommodates inputs of 600VAC direct or up to 15KVAC from PT’s
- 100 Measurements each second
- Monitors and records Power Demands or Disturbances
- True RMS VA (apparent power) and True Power, VIcos Ø -Maximum, minimum, average and present value for each, regardless of wave shape or distortion level
- 4 Categories of Voltage and Current Measurements
- 4 Categories of Power Factor Measurements
- Power Duty Cycle - Average "On" Time - Power Cycles-Estimated power cycles, Peak Demand Period
- Transient/Swell/Sag Detection 5 Categories
- Real Time Clock/Calendar - Displays present and elapsed time of monitoring
|
|
|
 |
|
|
Harmonic Energy Analyzer
As a Harmonic
Energy Analyzer, the 3030A tracks percent of total
harmonic distortion (%THD). The % THD indicates the
degree of non-sinusodial waveshape the voltage or current
exhibits. Individual harmonic values (1st-50th) are
optionally available.
Line Disturbance Analyzer
As a Line
Disturbance Analyzer, the 3030A tracks voltage or current
disturbances (transients -up to 999 events). Amplitude,
duration and risetime are continously monitored; largest
transient data is logged. Swells and sags may also be
detected and logged.
Power - Energy Data Logger
As a Demand
Analyzer, the 3030A tracks power consumption, Energy,
Cost, Harmonic Distortion, True Watts, Kilowatt-Hours
(KWHr),True RMS Volts, Amps, True Power Factor (W/VA) and
more. Graphs and individual waveforms can be uploaded to
a PC for analysis.
|
|
Single and Three
Phase Harmonic Energy Analyzer - Data Logger
- The Valhalla
3030A is one of the smallest, most cost effective
instruments for the measurement and analysis of single
and three phase electric power. It lets the user
analyze energy usage and costs. You can evaluate power
quality, troubleshoot wiring and equipment energy use,
and perform true three phase measurements for less than
the cost of a single phase instrument.
- The Valhalla
3030A capability includes: single and three phase
voltage, current, power (watts), energy (KWHrs), cost,
power factor (p.f.), total harmonic distortion,
transients (spikes), frequency, duty cycle, and power
cycles. It also stores in non-volatile memory two
complete sets of waveforms (saves 14 signals-
3Ø) as standard.
- The Valhalla
3030A also measures 3Ø delta voltages - (i.e.
phase to phase voltages) and current levels as
standard. Primary/secondary ratios for current
transformers (CT¹s) and potential transformers
(PT¹s) can be entered into the unit for recording
of primary values when monitoring secondary outputs, to
provide automatic scaling for energy measurements (i.e.
Kilowatt Hours).
- The Valhalla
3030A measures each phase to phase voltage and current
in a three phase delta configuration. Total 3Ø
power factor may also be displayed. The PC Control
Analysis software provides simultaneous voltage and
current measurement sequencing. There is no waiting or
cycle time delays between the voltage or current
data.
|

3030A Analyzer and
Hardware |
Standard
Features
- 3 Voltage
Inputs, 4 Current Inputs - A, B, C and Neutral Inputs
for single and three phase (3 wire "delta" or 4 wire
"wye") circuits - accepts user CT & PT
ratios
- 100
Measurements each second - Answers to all common
questions about electric power: present values,
summaries and estimates.
- Monitor
Demand or Disturbances - Summary data available on the
display, demand data logged values may be uploaded to a
computer for display and analysis
- True RMS VA
(apparent power) and True Power -Maximum, minimum,
average and present value for each, regardless of
waveshape or distortion level
- 12 Voltage
Measurements - Maximum, minimum, average, and present
value for each phase to phase voltage
- 16 Current
Measurements - Maximum, minimum, average and present
value for A, B, C and neutral currents
- Duty Cycle -
Average "On" Time - Power Cycles-Estimated power cycles
- per Hr., per day, per week - Great diagnostic tool
for thermostatically controlled loads
- 16 Power
Factor Measurements - Max., min., average/ present
value of true power factor for each phase &
total
- User Control
of Basic Settings - Change logging period, time, date,
greeting, etc.
- Internal
Battery to Bridge Power Failures - Internal
rechargeable battery pack can operate unit for 10 hrs
between charges
- Transient/Swell/Sag Detection - Magnitude,
duration, risetime, and time/date of worst transient
swells and sags of at least 1 second in duration are
recorded while monitoring consumption
- Elapsed KWHr
& True Cost, Estimated Energy & Cost per Hr., /Mo., /
Yr. - Actual energy use, energy estimates and costs are
updated each second
- Peak Demand
Period - Finds period and magnitude of the (maximum)
peak demand - amplitude and time/date
- Real Time
Clock/Calendar - Displays present and elapsed time of
monitoring
- Easy to Use
and Understand -Menu driven format
|
|
|
True RMS
Current
Current measurements
- A,B,C, and neutral current inputs for 1Ø and
3Ø circuits. Maximum, minimum, average, and present
value for each phase to neutral current. True RMS values
provide accurate measurements regardless of waveshape. The
photo above shows phase A current (Ia) levels. |
|
|
True RMS Voltage
Display
12 True RMS voltage
measurements for 1Ø and 3Ø applications
including maximum, minimum, average, and present values.
The 3030A true RMS voltage levels provide accurate
measurements for distorted or non-sinusoidal wave
forms. |
|

PC Control
Analysis
PC
control/analysis capability allows high resolution
voltage and current wave forms to be uploaded to your
PC.
|
|
|
True RMS
Power
8 true power
measurements as well as apparent power (VA). Both
parameters (true power, and VA) are measurable as a
maximum, minimum, average, and present values for any phase
(A, B, C, and total power). |
|
|
3030A frequency
display
Frequency and Duty
Cycle measurements are also available. Ideal for field or
on-site use, the Valhalla 3030A can easily perform "power
on" duty cycle ratios ( % ON/OFF) for motors,
refrigerators, compressors. air-conditioners, and a variety
of thermostatically or relay controlled devices.
|
|

Harmonic and PC
Control
Harmonic and PC
control analysis links the measured waveform for graphic
display of harmonics from the 1st thru 50th to your
PC.
|
|
|
Power
Factor
12 Power Factor
measurements (W/ VA) accurate from zero to unity p.f. for
all phases, maximum, minimum, average, present value,and
total p.f. are available as standard. The photo above shows
phase A to neutral power factor readings. |
|
|
Total Harmonic
Distortion display
% THD - Total
Harmonic Distortion of any of 3 voltages or 4 currents upon
demand is standard. Individual harmonics (option "HARM" ,
1st - 15th) may be expanded to the 50th harmonic with the
PC control analysis option. |
|
|
Transient Spike
Measurement display
As a line
disturbance analyzer, i.e. above, the Valhalla 3030A
displays that 145 transients were detected at potentials
greater than 241 volts peak. The Valhalla 3030A user may
set disturbance trigger threshold levels that can capture
transients at any established level. |
|

Line
Disturbance Analyzer
Fluctuations in
power consumption or device under test power levels may
be graphically displayed or imported into your
presentation or spreadsheet software.
|
|
|
Peak Demand
Period Measurement display
As a power
Data Logger the Valhalla 3030A records the peak demand
period (i.e. period of day) when the most energy is used,
along with the average power demand for each demand
interval automatically. The Valhalla 3030A allows complete
interval entry flexibility, from 1 second to a 99 minute
demand period. |
|
|
Est.
Cost/Yr.
Ideal for energy
audits, the Valhalla 3030A measures actual energy use (KWHr
& true cost), estimated energy use per hour, day, month,
and year. It also accepts user adjustable utility
rates. |
|
Specifications 
|
|
Size:
|
|
4” Wide ´ 8” Long ´ 1.75” Deep
|
Weight:
|
|
Less than 2 pounds
|
Operating Range:
|
|
0 - 50 degrees C (32 - 122 degrees F)
|
|
Relative humidity to 70% (non-condensing)
|
Power Requirement:
|
|
12 VDC @ 50 mA, wall mount power supply included Internal Ni-Cad operates up to 10 hours after overnight charge
|
Voltage:
|
|
Input Range:
|
1 - 600 Vrms steady-state (direct input),
|
|
|
or 600 – 5,000 Vrms with 5KVP probes,
|
|
|
or 600 – 15,000 Vrms with 5KVP probes.
|
|
Display Range:
|
1 - 6 megavolts (using input ratios)
|
|
Accuracy:
|
0.5%
|
|
Frequency Response:
|
No derating of accuracy for harmonics through 25th harmonic (1500 Hz for 60 Hz fundamental)
|
Current:
|
|
Input Range:
|
0.01 - 5000 Amps, AC or DC with the proper current probe attached
|
|
|
With HA10: .01 - 10 Amps
|
|
|
With HA100: 0.1 - 100 Amps
|
|
|
With HA1000: 1 - 1000 Amps
|
|
|
With FX3000: 10 – 3000 Amps
|
|
|
With FX5000: 100 - 5000 Amps
|
|
|
With DC600: 5 - 600 Amps DC
|
|
|
6 autoranges
|
|
Display Range:
|
1mA - 6 megamps (using input ratios)
|
|
Accuracy:
|
0.5% plus accuracy of current probe
|
|
Frequency Response:
|
dependent on current probe attached
|
|
|
With HA1000: no derating of accuracy for harmonics through the 25th harmonic (1500 Hz for 60 Hz fundamental)
|
Frequency:
|
|
Range:
|
DC, 45 - 66 Hz, 360 – 440 Hz fundamental frequency
|
|
|
DC and 45 - 1650 Hz included in RMS 45 - 3000 Hz for harmonic measurements
|
|
Accuracy:
|
0.5%
|
Power, Energy, Cost, Power Factor:
|
|
Display Range:
|
1 watt - 60 megawatts (using input ratios)
|
|
Accuracy:
|
1% plus accuracy of current probe
|
Harmonic Distortion:
|
|
Range:
|
Basic unit has THD only
|
|
|
With Harmonic Analysis Option, individual harmonics through 15th (900 Hz)
|
|
|
With Harmonic Analysis and PowerSight Manager software, harmonics through 50th (3000 Hz)
|
|
Accuracy:
|
To within 1% of fundamental
|
Transient Detection:
|
|
Minimum duration to guarantee capture:
|
32 msec
|
|
Measurable Range of Magnitude:
|
±2500 Vpk
|
Captured Waveforms:
|
|
Quantity:
|
14 waveforms organized into 2 time-coincident sets of 7 each (3 voltages and 4 currents)
|
|
Complete Systems
|
| Software
|
| Current / Voltage Probes
|
| Accessories
|
| Options
|
|